Gas filled capillary Bottom connection Temprature guage Specification

  • Thread
  • 1/2 BSP (M) Bottom Connection
  • Outer Size
  • 63mm, 100mm, 150mm Dial
  • Measuring Range
  • -40C to 600C
  • Sensor Type
  • Gas Filled Capillary
  • Glass Size
  • Standard/Customized
  • Display
  • Analog Dial
  • Case
  • Stainless Steel (SS304/SS316)
  • Bourdon Tube
  • Stainless Steel (SS316)
  • Material
  • Stainless Steel/Brass
  • Working Presssure
  • Up to 25 bar
  • Seal Material
  • PTFE or Neoprene
  • Product Type
  • Temprature guage
  • Grade
  • Industrial
  • Accuracy
  • 1% %
  • Capillary Length
  • Standard 1 mtr, up to 10 mtrs Available
  • Dial Marking
  • Customized as per Requirement
  • Filling Medium
  • Inert Gas
  • Ambient Temperature
  • Max 60C
  • Sensing Bulb Dimensions
  • 6mm/8mm/10mm OD x length as required
  • Pointer
  • Micrometer Adjustable
  • Mounting
  • Bottom Connection
  • Operating Temperature
  • -20C to +80C (Case)
  • Sensing Bulb Material
  • Stainless Steel
  • Window Material
  • Acrylic/Glass
  • Enclosure Protection
  • IP65
 

Gas filled capillary Bottom connection Temprature guage Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Supply Ability
  • 100 Per Week
  • Delivery Time
  • 7 Days
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Domestic Market
  • All India
 

About Gas filled capillary Bottom connection Temprature guage

GAS FILLED (with Contacts) Back Connection Every Angle a c Gas filled sensing element a c Dial Size 100/ 150mm a c Mounting Bottom/ Back a c Range(-) 50 to 650C measuring range 0 a c Weatherproof to IP68 per IS/IEC 60529:2001

Robust & Versatile Construction

Designed with premium materials such as stainless steel (SS304/SS316) for the body and bourdon tube, this temperature gauge ensures exceptional durability. Its enclosure meets IP65 standards, providing reliable protection against dust and water ingress, making it ideal for challenging industrial and chemical environments.


Customizable for Your Needs

Select from a variety of dial sizes (63mm, 100mm, 150mm), capillary lengths up to 10 meters, and customized dial markings to fit exact application requirements. The adjustable micrometer pointer allows users to fine-tune readings, while multiple mounting and window options cater to diverse setups.


Precision & Safety Assured

Benefit from 1% accuracy and robust sealing with PTFE or Neoprene. The gauge measures temperatures from -40C to 600C, suitable for most industrial processes. The inert gas filling and stainless steel sensing bulb ensure long lifespan, safety, and consistent performance in high-pressure (up to 25 bar) conditions.

FAQ's of Gas filled capillary Bottom connection Temprature guage:


Q: How does a gas filled capillary bottom connection temperature gauge operate?

A: This temperature gauge utilizes an inert gas-filled capillary system. Temperature changes at the sensing bulb (made of stainless steel) cause pressure changes in the gas, which move the pointer on the analog dial, providing accurate readings.

Q: What are the benefits of choosing different capillary lengths?

A: Selecting a custom capillary length up to 10 meters allows you to position the dial at a safe or convenient distance from the measurement point, enhancing both safety and usability in complex or hazardous environments.

Q: When should I specify customized dial markings or dial sizes?

A: Customized dial markings and sizes are recommended when your application requires specific temperature ranges or improved visibility. Choose from 63mm, 100mm, or 150mm dial diameters and request custom printing for unique process requirements.

Q: Where can this temperature gauge be used?

A: It is ideal for use in industrial processes, chemical and petrochemical plants, OEM systems, laboratories, and HVAC applications due to its robust design and high accuracy.

Q: What is the process for installing the bottom connection temperature gauge?

A: Install the gauge using the 1/2 BSP (M) threaded bottom connection, ensuring a secure fit. Position the sensing bulb at the target temperature point and route the capillary tube to the display dial's location. Proper sealing (PTFE/Neoprene) prevents leakage and maintains system integrity.

Q: How do I select the optimal sensing bulb size and material?

A: Choose the sensing bulb's diameter (6mm, 8mm, or 10mm OD) and length based on your application's requirements. Stainless steel is preferred for its corrosion resistance and compatibility with various media.

Q: What makes this gauge suitable for harsh environments?

A: With an IP65-rated stainless steel enclosure, inert gas filling, and durable construction, the gauge is resistant to dust, moisture, chemical exposure, and high-pressure conditions (up to 25 bar), ensuring reliability and longevity in tough industrial settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Temperature Gauge Category

Bimetal Temperature Gauge

Bimetal Temperature Gauge

Price 800 INR / Unit

Minimum Order Quantity : 1 Unit

Seal Material : Silicone Rubber Gasket

Outer Size : 100 mm

Length : 1 feet

Thread : 1/2 BSP



Back to top